Nullifire FB750, Coated Batts for use within Walls and Floors
Nullifire FB750, lightweight fire barrier
Nullifire FB750, application
Nullifire FB750, elastomeric, ablative water based sealant.
Nullifire FB750, pipe sealant
Nullifire FB750, cable tray sealant
Nullifire FB750, trim to size board
Nullifire FB750, customisable size
  • Nullifire FB750, Coated Batts for use within Walls and Floors
  • Nullifire FB750, lightweight fire barrier
  • Nullifire FB750, application
  • Nullifire FB750, elastomeric, ablative water based sealant.
  • Nullifire FB750, pipe sealant
  • Nullifire FB750, cable tray sealant
  • Nullifire FB750, trim to size board
  • Nullifire FB750, customisable size

Nullifire FB750

Coated Batts for use within Walls and Floors

A lightweight, 4 hour fire barrier comprising of a mineral fibre board with an elastomeric, ablative water based sealant.

Basic Uses

When used in conjunction with FS702, the FB750 board is suitable for sealing around the following service types: non-combustible pipes, cable trays, ladders and baskets (perforated or non-perforated), armoured cables, data cables, HV cable, cable bundles up to 100 mm, dampers and ductwork.

Typical areas of use include: health and leisure facilities, schools, universities, commercial buildings, retail and industrial units.

Nullifire FB750 Application Tips

FAQ
  • How do I install FB750 Intubatt?
    ​​​​​​Before installation, make sure that the opening is clean and free from dust and debris. FB750 Intubatt must be compressed and mounted on two or more opposing sides. If the opening does not allow the above to be done, mechanical support may be required.
  • Can I install FB750 without any sealants?
    No, all perimeter edges, service abutments, joints or any de-laminations should be injected with a 10mm fillet of FS702 Intumastic.
     
  • How to repair damaged batts?
    Examine the seal, ensure that the seal composition complies with Nullifire methodology. Repairs can be carried out by injecting FS702 Intumastic into the damaged area. Repairs to fire seals are usually required only when additional services have been added or existing services have been removed. Repair of a badly constructed or unstable primary seal is not recommended.
     
  • What is the density of the mineral wool for FB750 and what is the thickness of the firestop coating?
    The density of the mineral wool for FB750 is 140kg/m(180kg/m3 is upon request) and the dry thickness of the coating is 1mm DFT.
     